|
Publications - Peer Review Journals:
1) McAfee PC, Farey ID, Sutterlin CE, Gurr KR, Warden KE, Cunningham BW: Device
Related Osteoporosis with Spinal Instrumentation. A Canine Model. Spine, Vol.14
No.9, pp. 919-926, September, 1989. 1989 VOLVO AWARD for Basic Science Research
in Low Back Pain.
2) Ruland CM, McAfee PC, Warden KE, Cunningham BW: Triangulation of Pedicular
Instrumentation: A Biomechanical Analysis. Spine Vol.16 No 6S pp. S270-S276.
1991.
3) McAfee PC, Farey ID, Sutterlin CE, Gurr KR, Warden KE, Cunningham BW: The
Effect of Spinal Implant Rigidity on Vertebral Bone Density: A Canine Model.
SPINE Vol.16 No.6S pp.S190-S197. 1991.
4) Shirado O, Zdeblick TA, McAfee PC, Cunningham BW, DeGroot H, Warden KE:
Quantitative Histologic Study of the Influence of Anterior Spinal
Instrumentation and Biodegradable Polymer on Lumbar Interbody Fusion After
Corpectomy: A Canine Model. Spine Vol.17 No.7 pp.795-803. 1992.
5) McCord DH, Cunningham BW, Shono Y, Myers JJ, McAfee PC: Biomechanical
Analysis of Lumbosacral Fixation - 1991 North American Spine Society (NASS)
Award and The 1991 American Orthopaedic Association (AOA) Award. Spine, Vol.17
No.8S pp.S235-S243, 1992.
6) Brantigan JW, Cunningham BW, Shono Y, Warden KE, McAfee PC, Steffee AD: The
Use of A Carbon Fiber Implant in Reconstructing Anterior Spinal Column Defects.
Orthopaedic Transactions 16:139-140, 1992
7) Brantigan JW, Cunningham BW, Warden KE, McAfee PC, Steffee AD: Compression
Strength of Donor Bone for Posterior Lumbar Interbody Fusion. Spine Vol.18 No.9
pp.1213-1221, 1993.
8) Cunningham BW, Sefter JC, Shono Y, McAfee PC: Static and Cyclical
Biomechanical Analysis of Pedicle Screw Spinal Constructs. Spine Vol.18 No.12
pp.1677-1688, 1993.
9) Shono Y, McAfee PC, Cunningham BW: A Biomechanical Analysis of Decompression
and Reconstruction Methods in The Cervical Spine - Emphasis on a Carbon Fiber
Composite - 1991 CSRS Resident Award Paper. JBJS Vol.75-A, No.11, pp.1674-1684,
November, 1993.
10) Shono Y, McAfee PC, Cunningham BW: The Pathomechanics of Compression
Injuries in the Cervical Spine. Non-Destructive and Destructive Investigative
Methods - 1992 CSRS Research Award Paper. Spine Vol.18 No.14 pp.2009- 2019.
1993.
11) Shono Y, McAfee PC, Cunningham BW: Experimental Study of Thoracolumbar Burst
Fractures: A Radiographic and Biomechanical Analysis of Anterior and Posterior
Instrumentation Systems. Spine Vol.19 No.15, pp.1711-1722, 1994.
12) Brantigan JW, McAfee PC, Cunningham BW, Wang H, Orbegoso CM: Interbody
Lumbar Fusion Using a Carbon Fiber Cage Implant Versus Allograft Bone: An
Investigational Study in the Spanish Goat. Spine Vol.19 No.13 pp.1436-1444,
1994.
13) Curtis MJ, Jinnah RH, Cunningham BW, Wilson VD: Proximal Femoral Fractures -
Intramedullary or Extramedullary Fixation?. INJURY: British Journal of Accident
Surgery. Vol.25 No.2 pp.99-104, 1994.
14) Bhatia, D, Myerson, MS, Curtis MJ; Cunningham BW; Jinnah, RH: Anatomical
Restraints to Dislocation of the Second Metatarsophalangeal Joint and Assessment
of a Repair Technique - 1992 Richards Resident Award Paper.
JBJS Vol.76-A, No. 9:1371-1375.
15) Kotani, Y, Cunningham, BW, Abumi, K, McAfee, PC: Biomechanical Analysis of
Cervical Stabilization Systems: An Assessment of Transpedicular Screw Fixation
in the Cervical Spine. Spine Vol. 19. No 22 pp.2529-2539, 1994.
16) Fairbank A, Thomas D, Cunningham BW, Curtis M, and Jinnah RH: Stability of
Reamed and Unreamed Intramedullary Tibial Nails: A Biomechanical Study.
INJURY: British Journal of Accident Surgery. Vol.26 No.7:483-5, 1995.
17) Juliano PJ, Myerson MS, Cunningham BW: Biomechanical Assessment of A New
Tenodesis for Correction of Hallux Varus. Foot and Ankle International Journal,
Vol. 17, No 1:17-20, 1996.
18) Kotani Y, Cunningham BW, Cappuccino A, McAfee PC: The Role of Spinal
Instrumentation in Augmenting Posterolateral Fusion. Spine Vol. 21. No 3:
278-287, 1996.
19) Weis JC, Cunningham BW, Kanayama M, Parker L, McAfee PC: In-Vitro
Biomechanical Comparison of Multistrand Cables with Conventional Cervical
Stabilization. Spine Vol. 21, No. 18: 2108-2114, 1996.
20) Kanayama M, Cunningham BW, Weis JC, Parker LM, Kaneda K, McAfee PC:
Maturation of the Posterolateral Spinal Fusion and Its Effect on Load-Sharing of
Spinal Instrumentation. An In Vivo Sheep Model. 1998 Japanese Spine Research
Society Award for Basic Science Research JBJS Vol.79-A, No. 11:1710-1720, 1997.
21) Cunningham BW: Point of View Commentary - JF Cusick et al., Wire Fixation
Techniques of the Cervical Facets. Spine Vol. 22, No. 9:970-976, 1997.
22) Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC: The Effect of
Spinal Destabilization and Instrumentation on Lumbar Intradiscal Pressure. An In
Vitro Biomechanical Analysis. Spine Vol. 22, No. 22:2655-2663, 1997.
23) Kotani Y, Cunningham BW, Cappuccino A, Kaneda K, McAfee PC: The Effects of
Spinal Fixation and Destabilization on the Biomechanical and Histologic
Properties of Spinal Ligaments: An In Vivo Study. Spine Vol. 23, No. 6:672- 683,
1998.
24) Kanayama M, Cunningham BW, Weis JC, Parker LM, Kaneda K, McAfee PC: The
Effects of Rigid Spinal Instrumentation and Solid Bony Fusion on Spinal
Kinematics: A Posterolateral Spinal Arthrodesis Model. Spine Vol. 23, No.
7:767-773, 1998.
25) Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, Kanayama M, Fedder IL,
McAfee PC: Video-Assisted Thoracoscopic Surgery Versus Open Thoracotomy for
Anterior Thoracic Spinal Fusion. A Comparative Radiographic, Biomechanical, and
Histologic Analysis in a Sheep Model. Spine Vol. 23, No. 12:1333-1340, 1998.
26) Cunningham BW, DiStefano AF, Kirjanov NA, Levine SE, Schon LC: A Comparative
Mechanical Analysis of the Pointe Shoe Toe Box – An In Vitro Study. American
Journal of Sports Medicine Vol. 26, No. 4:555-561, 1998.
27) Kotani, Y, McNulty PS, Abumi K, Cunningham BW, Kaneda K, McAfee, PC: The
Role of Anteriomedial Foraminotomy and the Uncovertebral Joints in the Stability
of the Cervical Spine: A Biomechanical Study. Spine Vol. 23. No. 14:1559-1565,
1998.
28) Shono Y, Kaneda K, Abumi K, McAfee PC, Cunningham BW: Stability of Posterior
Spinal Instrumentation and its Effects on Adjacent Motion Segments in the
Lumbosacral Spine. Spine Vol. 23 No.14:1550-1558, 1998.
29) Cunningham BW, Kanayama M, Parker LM, Weis JC, Sefter JC, Fedder IL, McAfee
PC: Osteogenic Protein Versus Autologous Interbody Arthrodesis in the Sheep
Thoracic Spine. A Comparative Endoscopic Study Using the Bagby and Kuslich
Interbody Fusion Device. Spine Vol. 24, No. 6:509-518, 1999.
30) Spiegel DA, Drummond DS, Cunningham BW, Kanayama M, Haggerty CJ, McAfee PC,
and Dormans JP: Augmentation of an Anterior Solid Rod Construct with Threaded
Cortical Bone Dowels. A Biomechanical Study. Spine Vol. 24, No. 22:2300-2307,
1999.
31) Oda I, Abumi K, Sell LC, Haggerty CJ, Cunningham BW, Kaneda K, and McAfee
PC: Biomechanical Evaluation of Five Different Occipito-Atlanto-Axial Fixation
Techniques. Spine Vol. 24, No. 22:2377-2382, 1999.
32) Oda I, Cunningham BW, Abumi K, Kaneda K, and McAfee PC: The Stability of
Reconstruction Methods after Thoracolumbar Total Spondylectomy - An In Vitro
Investigation. 1998 Moe Exhibit Award, Scoliosis Research Society Spine Vol. 24,
No. 16:1634-1638, 1999.
33) Kanayama M, Ng JTW, Cunningham BW, Abumi K, Kaneda K, McAfee PC:
Biomechanical Analysis of Anterior Versus Circumferential Spinal Reconstruction
for Various Anatomic Stages of Tumor Lesions. Spine Vol. 24, No. 5:445-450,
1999.
34) Kanayama M, Cunningham BW, Sefter JC, Goldstein JA, Stewart G, Kaneda K,
McAfee PC: Does Spinal Instrumentation Influence the Healing Process of
Posterolateral Spinal Fusion?: An In Vivo Animal Model. Spine Vol. 24, No.
11:1058-1065, 1999.
35) Kotani Y, Cunningham BW, Parker LM, Kanayama M, McAfee PC: Static and
Fatigue Biomechanical Properties of Anterior Thoracolumbar Instrumentation
Systems: A Synthetic Testing Model. Spine Vol. 24, No. 14:1406-1413, 1999.
36) Oda I, Cunningham BW, Buckley RA, Goebel MJ, Haggerty CJ, Orbegoso CM,
McAfee PC: Does Spinal Kyphotic Deformity Influence the Biomechanical
Characteristics of the Adjacent Motion Segments? – An In Vivo Animal Model.
Spine Vol. 24, No. 20: 2139-2146, 1999.
37) McAfee PC, Cunningham BW, Lee GA, Orbegoso CM, Haggerty CJ, Fedder IL, and
Griffith SL: Revision Strategies for Salvaging or Improving Failed Cylindrical
Cages. Spine Vol. 24, No. 20: 2147-2153, 1999.
38) Polly DW Jr, Klemme WR, Cunningham BW, Burnette JB, Haggerty CJ, Oda I: The
Biomechanical Significance of Anterior Column Support in a Simulated
Single-Level Spinal Fusion. J Spinal Disord 2000 Feb;13(1):58-62.
39) Orchowski J, Polly DW Jr, Klemme WR, Oda, I and Cunningham BW: The Effect of
Kyphosis on the Mechanical Strength of a Long Segment Posterior Construct Using
a Synthetic Model. Spine Vol. 25, No. 13: 1644-1648, 2000.
40) Kanayama M, Cunningham BW, Haggerty CJ, Abumi K, Kaneda K, McAfee, PC: An
In-Vitro Biomechanical Investigation of the Stability and Stress-Shielding
Effect of Lumbar Interbody Fusion Devices: J. Neurosrugery. November 2000.
41) Oda I, Cunningham BW, Lee GA, Abumi K, Kaneda K, McAfee PC: Biomechanical
Properties of Anterior Thoracolumbar Multisegmental Fixation. An Analysis of
Construct Stiffness and Screw-Rod Strain. Spine Vol. 25, No. 18: 2303-2311,
2000.
42) Spiegel DA, Cunningham BW, Oda, I, Dormans JP, McAfee PC, and Drummond DS:
Anterior Vertebral Screw Strain With and Without Solid Interspace Support. Spine
Vol. 25, No. 21:2755-2761, 2000.
43) Henriques T, Cunningham BW, Olerud C, Shimamoto N, Lee GA, Larsson S and
McAfee PC: Biomechanical Comparison of Five Different Atlantoaxial Posterior
Fixation Techniques. Spine Vol. 25, No. 22:2877-2883, 2000.
44) Belmont PJ, Polly DW Jr., Cunningham BW, Klemme WR: The Effects of Hook
Pattern and Kyphotic Angulation on Mechanical Strength and Apical Rod Strain in
a Long-Segment Posterior Construct Using a Synthetic Model. Spine Vol. 26, No.
6:627-635, 2001.
45) Shimamoto N, Cunningham BW, Dmitriev AE, Minami A and McAfee PC:
Biomechanical Evaluation of Stand-Alone Interbody Fusion Cages in the Cervical
Spine. Spine Vol. 26, No. 19:E432, 2001.
46) Klemme WR, Cunningham BW, Polly DW: Microradiographic and Histopathologic
Findings in a Human Cage Explant After Two-Level Corpectomy A Case Report Spine
2002;27:E15-E17.
47) McAfee PC, Lee GA, Fedder IL, Cunningham BW: Anterior BAK Instrumentation
and Fusion: Complete Versus Partial Discectomy. Clin Ortho Rel Res 394: 55-63,
2002.
48) Cunningham BW and Polly DW: The Use of Interbody Cage Devices for Spinal
Deformity: A Biomechanical Perspective. Clin Ortho Rel Res 394: 72-83, 2002.
49) Oda I, Abumi K, Cunningham BW, Kaneda K, McAfee PC: An In-Vitro Human
Cadaveric Study Investigating the Biomechanical Properties of the Thoracic Spine
Spine Vol. 27, No. 3:E64-E70, 2002.
50) Cunningham BW, Shimamoto N, Sefter JC, Dmitriev AE, Orbegoso CM, McCarthy EF,
Fedder IL, McAfee, PC: Osseointegration of Autograft versus Osteogenic Protein-1
in Posterolateral Spinal Arthrodesis: Emphasis on the Comparative Mechanisms of
Bone Induction. The Spine Journal 2:11-24, 2002. 2001 North American Spine
Society Basic Science Research Award.
51) Cunningham BW, Dmitriev AE, Sefter JC, Naseef GS, McAfee PC: The Use of
Autologous Growth Factors versus Autogenous Graft for Anterior Cervical
Interbody Fusion. An In-Vivo Goat Model. In Press for Journal of Spine (January
2003 Edition).
52) Cunningham BW, Orbegoso CM, Dmitriev AE, Hallab NJ, Sefter JC, McAfee PC:
The Effect of Titanium Particulate on Development and Maintenance of a
Posterolateral Spinal Arthrodesis. - An In-Vivo Rabbit Model – Spine Vol. 27,
No. 18:1971-1981, 2002.
53) Cunningham BW, Lowery GL, Serhan HA, Dmitriev AE, Orbegoso CM, McAfee PC,
Fraser RF, Ross RE, Kulkarni SS: Total Disc Replacement Arthroplasty using the
Acroflex® Lumbar Disc: An Non-Human Primate Model.
Eur Spine J. 11(2)S115-123, 2002.
54) Tis, JE, Klemme WR, Kirk KL, Murphy KP and Cunningham BW: Braided Hamstring
Tendons for Reconstruction of the Anterior Cruciate Ligament. The American
Journal of Sports Medicine, 30, 5:684-688, 2002.
55) Cunningham BW, Lewis SJ, Long J, Dmitriev AE, Linville DA and Bridwell KH:
Biomechanical Evaluation of Lumbosacral Reconstruction Techniques for
Spondylolisthesis. Spine Vol. 27, No. 21:2321-2327, 2002.
56) Lebwohl NA, Cunningham BW, Dmitriev A, Shimamoto N, Gooch L, Devlin V,
Boachie-Adjei O, Wagner TA: Biomechanical Comparison of Lumbosacral Fixation
Techniques in a Calf Spine Model. Spine Vol. 27, No. 21:2312-20, 2002.
57) Oda I, Abumi K, Kaneda K, Cunningham BW, McAfee PC. Biomechanical
significance of discectomy, rib-head resection, and facetectomy in scoliosis
surgery of the thoracic spine. 2002 Best Paper – JSRS The Journal of Japanese
Scoliosis Research Society Vol. 17, No. 1: 23-28, 2002.
58) Cunningham, BW, Orbegoso CM, Dmitriev AE, Hallab NJ, Sefter JC, Asdourian
PL, McAfee PC: The Effect of Spinal Instrumentation Particulate Wear Debris - An
In-Vivo Rabbit Model and Applied Clinical Study of Retrieved Instrumentation
Cases - 2002 North American Spine Society Basic Science Research Award. The
Spine Journal 3:19-32, 2003.
59) McAfee PC, Cunningham BW, Orbegoso CM, Sefter JC, Dmitriev AE, Fedder IL:
Analysis of Porous Ingrowth in Intervertebral Disc Prosthesis: A Non- Human
Primate Model. 2001 Moe Exhibit Award, Scoliosis Research Society. Spine
28(4):332-340, 2003.
60) Polly DW, Cunningham BW, Kuklo TR, Lenke LG, Oda I, Schroeder TM, Klemme WR.
“Anterior Thoracic Scoliosis Constructs: Effect of Rod Diameter and
Intervertebral Cages on Multi-segmental Construct Stability. The Spine
Journal 3:213-219,2003.
61) Lehman RA, Polly DW, Kuklo TR, Cunningham BW, Kirk KL, Belmont PJ: Straight
Forward Versus Anatomic Trajectory Technique of Thoracic Pedicle Screw Fixation:
A Biomechanical Analysis. Spine 28 (18) 2058-2065, 2003.
62) Betz RR, Cunningham BW, Selgrath C, Drewry T and Sherman MC: Preclinical
Testing of a Wedge-Rod System for Fusionless Correction of Scoliosis. Spine 28
(20S) S275-S278, 2003.
63) McAfee PC, Polly DW, Cunningham BW, Gaines R, Hallab N, Lubicky J, Lenke L
and Bridwell K: Clinical Summary Statement – 2003 SRS Focus Edition. Spine 28
(20S) S196, 2003.
64) Cunningham BW, Hallab NJ, Polly DW, Gaines R, Lubicky J and McAfee PC: Basic
Science Summary Statement – 2003 SRS Focus Edition. Spine 28 (20S) S195, 2003.
65) McAfee PC, Cunningham BW, Dmitriev A, Hu N, Kim SW, Cappuccino A and Pimenta
L: Cervical Disc Replacement – Porous Coated Motion Prosthesis: A Comparative
Biomechanical Analysis Showing the Key Role of the Posterior Longitudinal
Ligament. Spine 28 (20S) S176-S185, 2003.
66) McAfee PC, Fedder IL, Saiedy S, Shucosky EM, Cunningham BW: Experimental
Design of Total Disc Replacement – Experience with a Prospective Randomized
Study of the SB Charite. Spine 28 (20S) S153-S162, 2003.
67) Hallab NJ, Cunningham BW and Jacobs JJ: Spinal Implant Debris-Induced
Osteolysis. Spine 28 (20S) S125-S138, 2003.
68) Cunningham BW, Dmitriev AE, Hu N, and McAfee PC: General Principles of Total
Disc Replacement Arthroplasty: Seventeen Cases in a Nonhuman Primate Model.
Spine 28 (20S) S118-S124, 2003.
69) Cunningham BW, Gordon JD, Dmitriev AE, Hu N, and McAfee PC: Biomechanical
Evaluation of Total Disc Replacement Arthroplasty: An In-Vitro Human Cadaveric
Model. Spine 28 (20S) S110-S117, 2003.
70) McAfee PC, Fedder IL, Saiedy S, Shucosky EM, Cunningham BW: SB Charite Disc
Replacement . Report of 60 Prospective Randomized Cases in a U.S Center. Journal
of Spinal Disorders and Techniques 16 (4) 424-433.
71) Jahng TA, Fu TS, Cunningham BW, Dmitriev AE, Kim DH: Endoscopic Instrumented
PosterolateralLumbar Fusion with Healos and Recombinant Human Growth /
Differentiation Factor-5. Neurosurgery 54(1):171-80; 2004.
72) Ito S, Ivancic PC, Panjabi MM and Cunningham BW: Soft Tissue Injury
Threshold During Simulated Whiplash: A Biomechanical Investigation. Spine
29,9:979-987, 2004.
73) Pearson AM, Panjabi MM, Ivancic PC, Ito S, Cunningham BW, Rubin W, Gimenez
SE: Frontal Impact Causes Ligamentous Cervical Spine Injury.
Spine. 15;30(16):1852-8, 2005
74) Cunningham BW: Basic Scientific Considerations in Total Disc Arthroplasty.
The Spine Journal 4:219S-230S, 2004.
75) Guyer RD, McAfee PC, Hochschuler SH, Blumenthal SL, Fedder IL, Ohnmeiss DD,
Cunningham BW: Prospective Randomized Study of the Charite Artificial Disc: Data
from Two Investigational Centers. Spine Journal 4:252S-259S, 2004.
76) Shikinami Y, Kotani Y, Cunningham BW, Abumi K and Kaneda K: A Biomimetric
Artificial Disc with Improved Mechanical Properties Compared to Biological
Intervertebral Discs. Advanced Functional Materials 14:11, 1039-1046, 2004.
77) Kotani Y, Cunningham BW, Abumi K, Dmitriev AE, Ito M, Shikinami Y, McAfee
PC, Minami A: Multidirectional Flexibility Analysis of Cervical Artificial Disc
reconstruction: In-Vitro Human Cadaveric Spine Model. J Nuerosurg Spine
2:188-194, 2005.
78) McAfee PC, DeVine JG, Chaput CD, Prybis BG, Fedder IL, Cunningham BW,
Farrell DJ, Hess SJ, Vigna FE: The Indications for Interbody Fusion Cages in the
Treatment of Spondylolisthesis: Analysis of 120 Cases. Spine 15,30: S60-65,
2005.
79) Dmitriev AE, Cunningham BW, Hu N, Sell G, Vigna F, McAfee PC: Adjacent Level
Intradiscal Pressure and Segmental Kinematics Following A Cervical Total Disc
Replacement. Spine 30, 10: 1165-1172, 2005.
80) McAfee PC, Cunningham BW, Holsapple G, Adams K, Blumenthal S, Guyer RD,
Dmitriev A, Maxwell JH, Regan JJ, Isaza J: A Prospective, Randomized,
Multicenter Food and Drug Administration Investigational Device Exemption Study
of Lumbar Total Disc Replacement with the CHARITé Artificial Disc Versus Lumbar
Fusion. Part II: Evaluation of Radiographic Outcomes and Correlation of Surgical
Technique Accuracy with Clinical Outcomes. Spine 30, 14: 1576-1583, 2005.
81) Kotani Y, Cunningham BW, Abumi K, Dmitriev AE, Hu N, Ito M, Shikinami Y,
McAfee PC and Minami A: Multidirectional Flexibility Analysis of Anterior and
Posterior Lumbar Artificial Disc Reconstruction: In Vitro Human Cadaveric Spine
Model. Eur. Spine Journal 10, 586-, 2006.
82) McAfee PC, Geisler FH, Saiedy SS, Moore SV, Regan JJ, Guyer RD, Blumenthal
SL, Fedder IL, Tortolani PJ, Cunningham BW: Revisability of the Charite
Artificial Disc Replacement. Analysis of 688 Patients Enrolled in the U.S. IDE
Study of the Charite Artificial Disc. Spine, Vol. 31, No. 11:1217-1226, 2006.
83) Tominaga Y, Maak TG, Ivancic PC, Panjabi MM, Cunningham BW: Head-turned Rear
Impact Causing Dynamic Cervical Intervertebral Foramen Narrowing: Implications
for Ganglion and Nerve Root Injury. J Neurosurg Spine. 4(5):380-7, 2006.
84) Hu N, Cunningham BW, McAfee PC, Kim SW, Sefter JC, Cappuccino A, Pimenta L:
Porous Coated Motion Cervical Disc Replacement: A Biomechanical,
Histomorphometric, and Biologic Wear Analysis in a Caprine Model. Spine,
1;31(15):1666-73, 2006.
85) Tortolani PJ, Cunningham BW, Vigna F, Hu N, Zorn CM and McAfee PC: A
Comparison of Retraction Pressure During Anterior Cervical Plate Surgery and
Cervical Disc Replacement: a Cadaveric Study. J Spinal Disord Tech. 19(5):312-7,
2006.
86) McAfee PC, Cunningham BW, Hayes V, Sidiqi F, Dabbah M, Sefter JC, Hu N and
Beatson H: Biomechanical Analysis of Rotational Motions after Disc Arthroplasty:
Implications for Patients With Adult Deformities. Spine. 2006 Sep 1;31(19 Suppl):S152-60.
87) Cunningham BW, DeMuth GE, McAfee PC, Scott-Young M, Yoon KJ Blumenthal SL,
Guyer RD, Geisler FH, Regan, JJ, Conix B, Hes R, Pimenta L, Diaz R, Fedder IL,
Stadlan NY and Tortolani PJ: Survivorship Analysis of the CHARITE Artificial
Disc: Review of 1,938 Patients from Eight Leading International Spine Centers.
Roundtables in Spinal Surgery. Long Term Results of Lumbar Arthroplasty. Vol. 1,
No. 4:31-37, 2006.
88) Tortolani PJ, Cunningham BW, Eng M, McAfee PC, Holsapple GA,
Adams KA.
Prevalence of heterotopic ossification following total disc replacement. A
prospective, randomized study of two hundred and seventy-six patients. J Bone
Joint Surg Am. 2007 Jan;89(1):82-8.
89) Cunningham BW, Hu N, Zorn CM, Beatson HJ, McAfee PC: Comparative Fixation
Methods of Cervical Disc Arthroplasty versus Conventional Methods of Anterior
Cervical Arthrodesis: Serration, Teeth, Keels or Screws? Roundtables in Spine
Surgery, Vol 2, No. 1:3-12, 2007.
90) Cunningham BW, Hu N, Beatson HJ, Zorn CM, McAfee PC: Bioactive Titanium
Calcium Phosphate Coating for Disc Arthroplasty: Analysis of 68 Vertebral
Endplates Following 6 to 33 Months’ Implantation? Roundtables in Spine Surgery,
Vol 2, No. 1:13-26, 2007.
91) Tortolani PJ, Cunningham BW, Vigna FE, Hu N, Zorn CM, McAfee PC: A
Comparison of Retraction pressure During Anterior Cervical Plate Surgery and
Cervical Disc Replacement: A Cadaveric Study. Roundtables in Spine Surgery, Vol
2, No. 1:45-52, 2007.
92) McAfee PC, Pimenta L, Cappuccino A, Cunningham BW, Link HD: Porous Coated
Motion Comprehensive Modular System for Differential Indications. Roundtables in
Spine Surgery, Vol 2, No. 1:55-70, 2007.
93) Prybis BG, Tortolani PJ, Hu N, Zorn CM, McAfee PC, Cunningham BW: A
Comparative Biomechanical Analysis of Spinal Instability and Instrumentation of
the Cervicothoracic Junction: An In Vitro Human Cadaveric Model. J Spinal Disord
Tech. 2007 May 20 (3):233-238.
94) Pimenta L, McAfee PC, Cappuccino A, Cunningham BW, Diaz R, Coutinho E.
Superiority of Multilevel Cervical Arthroplasty Outcomes versus Single-Level
Outcomes: 229 Consecutive PCM Prostheses. Spine 20;32 (12):1337-44, 2007
Publications - Book Chapters:
1) Cunningham, BW et al.: “Video Assisted Spinal Surgery: Laboratory Protocol.”
In Regan JJ, McAfee PC, Mack MJ. Atlas of Endoscopic Spine Surgery. St. Louis:
Quality Medical Publishing, Inc., 1995, pp.18-26.
2) Goldstein JA, Cunningham BW, McAfee PC: “Spinal Instrumentation for Thoracic
and Lumbar Fractures.” In Rothman and Simeone (eds). The Spine Fourth Edition
Chapter. W.B. Saunders Company, Philadelphia 1998, pp.1037-1070.
3) Lee GA, Cunningham BW, McAfee PC: “Lumbosacral Instrumentation.” In Stuart
Weinstein (ed) The Pediatric Spine: Principles and Practice, Second Edition
Chapter 33:547-557. Lippincott Williams and Wilkins Publishing, Inc. 1999.
4) Cunningham BW: "A Biomechanical Approach to Posterior Spinal Instrumentation:
Principles and Applications. In Dewald (ed). Spinal Deformities: The
Comprehensive Text. Thieme Publishers, New York, NY. Chapter 59:589-600. 2003
5) McAfee, PC, Cunningham BW, Shimamoto N et al: SB Charité Disc Replacement:
Biologic Ingrowth Using a Non-Human Primate Model. In Buttner-Janz, Hochschuler
and McAfee (eds). The Artificial Disc. Springer-Verlag, Inc. Chapter 6:53-71,
2003.
6) Polly DW, Klemme WR, Kuklo TR, Belmont PJ, and Cunningham, BW.: “Biomechanics
of Anterior Column Support” In Lenke and Betz (eds). Modern Anterior Scoliosis
Surgery. St. Louis: Quality Medical Publishing, Inc., 2003, pp.27-36.
7) Cunningham, BW, Bagby GW and McAfee PC: Design of Interbody Fusion Cages:
Historical Considerations and Current Perspectives in Cage Technology. In
Corbin, Connolly, Yuan, Bao, and Boden (eds). Advanced Spinal Surgical
Technologies. Chapter. 29 St. Louis: Quality Medical Publishing, Inc., 2005.
8) Cunningham BW: Biomechanics and Pre-Clinical Studies. In CHARITE Teaching
Modules. St. Louis: Quality Medical Publishing, Inc., Fall 2004 (In Press).
9) McAfee PC and Cunningham BW: The Cervitech Porous Coated Motion Cervical Disc
Replacement. In Guyer and Zigler (eds). Spinal Arthroplasty – A New Era in Spine
Care. St. Louis: Quality Medical Publishing, Inc., Chapter 14:239-254, 2005.
10) Cunningham BW, Anderson PA, Zorn CM: Pre-Clinical Evaluation of Dynamic
Spinal Stabilization: – Animal Models and Basic Scientific Methods – Elsevier In
Press. |